Matspec

Products · Siniat · Gypsum boards and sheets

Siniat E Board

Declared by the maker, not tested by Matspec. A value is what the document named beside it stated on the day it was read.

Maker
Siniat
Family
Gypsum boards and sheets (Pr_25_71_35)
Type under EN 520:2004+A1:2009
D
Declared as
Siniat E Board, Siniat Contour Board (Plasterboard Type D)
Intended use, as declared
General building construction
Status
current
Last checked
2026-11-22

What its maker declares

UKCA declaration UKSI-00520-004-22GB, dated 2024-10-04

Characteristic, as namedForDeclaredSpecification cited
Flexural strength - Fflexural strength6 mm, transverse≥100NEN 520:2004+A1:2009
6 mm, longitudinal≥258N
12.5 mm, transverse≥210N
12.5 mm, longitudinal≥550N
Shear strength-shear strengthNPDno performance determined: the maker declares none
Reaction to fire - R2Freaction to fireA2,-s1,d0 (class A2-s1,d0)EN 520:2004+A1:2009
Airborne sound insulation - Rairborne sound insulationsee literaturenot on this document: the maker points to its own literature
Acoustic absorption - αacoustic absorptionsee literaturenot on this document: the maker points to its own literature
Water vapour permeability - µwater vapour resistance factor10EN 12524:2000
Thermal conductivity - λthermal conductivity0.25 W/m.KEN 12524:2000
Impact Resistance- →Iimpact resistancesee literaturenot on this document: the maker points to its own literature

CE declaration UKSI-00520-004-22, dated 2024-10-04

Characteristic, as namedForDeclaredSpecification cited
Flexural strength - Fflexural strength6 mm, transverse≥100NEN 520:2004+A1:2009
6 mm, longitudinal≥258N
12.5 mm, transverse≥210N
12.5 mm, longitudinal≥550N
Shear strength-shear strengthNPDno performance determined: the maker declares none
Reaction to fire - R2Freaction to fireA2,-s1,d0 (class A2-s1,d0)EN 520:2004+A1:2009
Airborne sound insulation - Rairborne sound insulationsee literaturenot on this document: the maker points to its own literature
Acoustic absorption - αacoustic absorptionsee literaturenot on this document: the maker points to its own literature
Water vapour permeability - µwater vapour resistance factor10EN 12524:2000
Thermal conductivity - λthermal conductivity0.25 W/m.KEN 12524:2000
Impact Resistance- →Iimpact resistancesee literaturenot on this document: the maker points to its own literature

The documents these come from

DocumentNumberDatedAppliesStandardAssessmentFirst readLast checked
declaration, at the makerUKSI-00520-004-22GB2024-10-04UKCAEN 520:2004+A1:2009System 42026-11-222026-11-22
declaration, at the makerUKSI-00520-004-222024-10-04CEEN 520:2004+A1:2009System 42026-11-222026-11-22

Names and codes

Sizes

No size read yet: sizes are on the maker's data sheet, not its declaration.

Listed by

No seller's listing read yet.

As data

/products/siniat-e-board.json: this page as data, every row, as it stands today. The dated history of changes is in the query layer.

History

DateWhat
2026-11-22First read: declaration UKSI-00520-004-22, dated 2024-10-04, 11 declared values on 8 lines.
2026-11-22First read: declaration UKSI-00520-004-22GB, dated 2024-10-04, 11 declared values on 8 lines.