{"slug":"siniat-fire-core-board","name":"Siniat Fire Core Board","maker":"siniat","maker_name":"Siniat","family":"pr-25-71-35","family_name":"Gypsum boards and sheets","family_code":"Pr_25_71_35","status":"current","product_type":"Siniat Fire Core Board (Gypsum plasterboard type D,F,H1,I and R)","type_letters":["D","F","H1","I","R"],"intended_use":"General building construction","names":[{"name":"UKSI-00520-015-22","kind":"declaration_number","read_at":"https://media.siniat.co.uk/cert_290616_gb/original/-392906995/dop_uksi-00520-015-22_siniat_firecoreboard_ce.pdf?brand=siniat&market=gb","read_on":"2026-11-22"},{"name":"UKSI-00520-015-22GB","kind":"declaration_number","read_at":"https://media.siniat.co.uk/cert_290617_gb/original/383006495/dop_uksi-00520-015-22gb_siniat_firecoreboard_ukca.pdf?brand=siniat&market=gb","read_on":"2026-11-22"},{"name":"Siniat Fire Core Board","kind":"name","read_at":"https://media.siniat.co.uk/cert_290616_gb/original/-392906995/dop_uksi-00520-015-22_siniat_firecoreboard_ce.pdf?brand=siniat&market=gb","read_on":"2026-11-22"}],"documents":[{"kind":"declaration","number":"UKSI-00520-015-22GB","dated":"2024-10-04","marking":"UKCA","standard":"EN 520:2004+A1:2009","assessment":"System 4","read_at":"https://media.siniat.co.uk/cert_290617_gb/original/383006495/dop_uksi-00520-015-22gb_siniat_firecoreboard_ukca.pdf?brand=siniat&market=gb","first_read":"2026-11-22","last_checked":"2026-11-22","fingerprint":"5be60459eab85c4d981cf800abc6f7e5da937f6ee392243dbd37ce1b197dfbba","versions_read":1},{"kind":"declaration","number":"UKSI-00520-015-22","dated":"2024-10-04","marking":"CE","standard":"EN 520:2004+A1:2009","assessment":"System 4","read_at":"https://media.siniat.co.uk/cert_290616_gb/original/-392906995/dop_uksi-00520-015-22_siniat_firecoreboard_ce.pdf?brand=siniat&market=gb","first_read":"2026-11-22","last_checked":"2026-11-22","fingerprint":"a215d166c6ba8bbbd213a7d48d88d2f859a7edf78545d268b0e4c9776542db4a","versions_read":1}],"declared":[{"line":1,"characteristic":"flexural_strength","as_named":"Flexural strength - F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"≥456N","kind":"number","bound":">=","value":456,"unit":"N","for":{"thickness_mm":19,"direction":"transverse"}},{"as_printed":"≥1102N","kind":"number","bound":">=","value":1102,"unit":"N","for":{"thickness_mm":19,"direction":"longitudinal"}}]},{"line":2,"characteristic":"shear_strength","as_named":"Shear strength-","specification":null,"from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"NPD","kind":"npd"}]},{"line":3,"characteristic":"reaction_to_fire","as_named":"Reaction to fire - R2F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"A2,-s1,d0","kind":"class","class":"A2-s1,d0"}]},{"line":4,"characteristic":"airborne_sound_insulation","as_named":"Airborne sound insulation - R","specification":null,"from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":5,"characteristic":"acoustic_absorption","as_named":"Acoustic absorption - α","specification":null,"from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":6,"characteristic":"water_vapour_resistance_factor","as_named":"Water vapour permeability - µ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"10","kind":"number","bound":"=","value":10,"unit":null}]},{"line":7,"characteristic":"thermal_conductivity","as_named":"Thermal conductivity - λ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"0.25 W/m.K","kind":"number","bound":"=","value":0.25,"unit":"W/m.K"}]},{"line":8,"characteristic":"impact_resistance","as_named":"Impact Resistance- →I","specification":null,"from":"declaration","document":"UKSI-00520-015-22GB","applies":"UKCA","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":1,"characteristic":"flexural_strength","as_named":"Flexural strength - F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"≥456N","kind":"number","bound":">=","value":456,"unit":"N","for":{"thickness_mm":19,"direction":"transverse"}},{"as_printed":"≥1102N","kind":"number","bound":">=","value":1102,"unit":"N","for":{"thickness_mm":19,"direction":"longitudinal"}}]},{"line":2,"characteristic":"shear_strength","as_named":"Shear strength-","specification":null,"from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"NPD","kind":"npd"}]},{"line":3,"characteristic":"reaction_to_fire","as_named":"Reaction to fire - R2F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"A2,-s1,d0","kind":"class","class":"A2-s1,d0"}]},{"line":4,"characteristic":"airborne_sound_insulation","as_named":"Airborne sound insulation - R","specification":null,"from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":5,"characteristic":"acoustic_absorption","as_named":"Acoustic absorption - α","specification":null,"from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":6,"characteristic":"water_vapour_resistance_factor","as_named":"Water vapour permeability - µ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"10","kind":"number","bound":"=","value":10,"unit":null}]},{"line":7,"characteristic":"thermal_conductivity","as_named":"Thermal conductivity - λ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"0.25 W/m.K","kind":"number","bound":"=","value":0.25,"unit":"W/m.K"}]},{"line":8,"characteristic":"impact_resistance","as_named":"Impact Resistance- →I","specification":null,"from":"declaration","document":"UKSI-00520-015-22","applies":"CE","values":[{"as_printed":"see literature","kind":"see_literature"}]}],"variants":[],"listed_by":[],"note":"Declared by the maker, not tested by Matspec. A value is what the document named beside it stated on the day it was read.","source":"https://media.siniat.co.uk/cert_290617_gb/original/383006495/dop_uksi-00520-015-22gb_siniat_firecoreboard_ukca.pdf?brand=siniat&market=gb","checked":"2026-11-22","page":"https://matspec.io/products/siniat-fire-core-board","history":{"firstRead":"2026-11-22","lastChanged":"2026-11-22","revisions":2,"changes":"https://matspec.io/api/query"}}