{"slug":"siniat-fire-mr-board","name":"Siniat Fire MR Board","maker":"siniat","maker_name":"Siniat","family":"pr-25-71-35","family_name":"Gypsum boards and sheets","family_code":"Pr_25_71_35","status":"current","product_type":"Siniat Fire MR Board (Gypsum plasterboard type D, F, H2)","type_letters":["D","F","H2"],"intended_use":"General building construction","names":[{"name":"UKSI-00520-013-22","kind":"declaration_number","read_at":"https://media.siniat.co.uk/cert_290613_gb/original/145248912/dop_uksi-00520-013-22_siniat_firemrboard_ce.pdf?brand=siniat&market=gb","read_on":"2026-11-22"},{"name":"UKSI-00520-013-22GB","kind":"declaration_number","read_at":"https://media.siniat.co.uk/cert_290614_gb/original/-392906995/dop_uksi-00520-013-22gb_siniat_firemrboard_ukca.pdf?brand=siniat&market=gb","read_on":"2026-11-22"},{"name":"Siniat Fire MR Board","kind":"name","read_at":"https://media.siniat.co.uk/cert_290613_gb/original/145248912/dop_uksi-00520-013-22_siniat_firemrboard_ce.pdf?brand=siniat&market=gb","read_on":"2026-11-22"}],"documents":[{"kind":"declaration","number":"UKSI-00520-013-22GB","dated":"2022-10-04","marking":"UKCA","standard":"EN 520:2004+A1:2009","assessment":"System 4","read_at":"https://media.siniat.co.uk/cert_290614_gb/original/-392906995/dop_uksi-00520-013-22gb_siniat_firemrboard_ukca.pdf?brand=siniat&market=gb","first_read":"2026-11-22","last_checked":"2026-11-22","fingerprint":"13e3bebd41e5ba63e704026732172c5f3be2c017820f50bbf1f263d254334e74","versions_read":1},{"kind":"declaration","number":"UKSI-00520-013-22","dated":"2024-10-04","marking":"CE","standard":"EN 520:2004+A1:2009","assessment":"System 4","read_at":"https://media.siniat.co.uk/cert_290613_gb/original/145248912/dop_uksi-00520-013-22_siniat_firemrboard_ce.pdf?brand=siniat&market=gb","first_read":"2026-11-22","last_checked":"2026-11-22","fingerprint":"865f5ac2b2594636420ecfd8c51e2a9e342735fdf3b22f9869cca2f99236a2ee","versions_read":1}],"declared":[{"line":1,"characteristic":"flexural_strength","as_named":"Flexural strength - F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"≥210N","kind":"number","bound":">=","value":210,"unit":"N","for":{"thickness_mm":12.5,"direction":"transverse"}},{"as_printed":"≥550N","kind":"number","bound":">=","value":550,"unit":"N","for":{"thickness_mm":12.5,"direction":"longitudinal"}},{"as_printed":"≥250N","kind":"number","bound":">=","value":250,"unit":"N","for":{"thickness_mm":15,"direction":"transverse"}},{"as_printed":"≥650N","kind":"number","bound":">=","value":650,"unit":"N","for":{"thickness_mm":15,"direction":"longitudinal"}}]},{"line":2,"characteristic":"shear_strength","as_named":"Shear strength-","specification":null,"from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"NPD","kind":"npd"}]},{"line":3,"characteristic":"reaction_to_fire","as_named":"Reaction to fire - R2F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"A2,-s1,d0","kind":"class","class":"A2-s1,d0"}]},{"line":4,"characteristic":"airborne_sound_insulation","as_named":"Airborne sound insulation - R","specification":null,"from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":5,"characteristic":"acoustic_absorption","as_named":"Acoustic absorption - α","specification":null,"from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":6,"characteristic":"water_vapour_resistance_factor","as_named":"Water vapour permeability - µ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"10","kind":"number","bound":"=","value":10,"unit":null}]},{"line":7,"characteristic":"thermal_conductivity","as_named":"Thermal conductivity - λ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"0.25 W/m.K","kind":"number","bound":"=","value":0.25,"unit":"W/m.K"}]},{"line":8,"characteristic":"impact_resistance","as_named":"Impact Resistance- →I","specification":null,"from":"declaration","document":"UKSI-00520-013-22GB","applies":"UKCA","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":1,"characteristic":"flexural_strength","as_named":"Flexural strength - F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"≥210N","kind":"number","bound":">=","value":210,"unit":"N","for":{"thickness_mm":12.5,"direction":"transverse"}},{"as_printed":"≥550N","kind":"number","bound":">=","value":550,"unit":"N","for":{"thickness_mm":12.5,"direction":"longitudinal"}},{"as_printed":"≥250N","kind":"number","bound":">=","value":250,"unit":"N","for":{"thickness_mm":15,"direction":"transverse"}},{"as_printed":"≥650N","kind":"number","bound":">=","value":650,"unit":"N","for":{"thickness_mm":15,"direction":"longitudinal"}}]},{"line":2,"characteristic":"shear_strength","as_named":"Shear strength-","specification":null,"from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"NPD","kind":"npd"}]},{"line":3,"characteristic":"reaction_to_fire","as_named":"Reaction to fire - R2F","specification":"EN 520:2004+A1:2009","from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"A2,-s1,d0","kind":"class","class":"A2-s1,d0"}]},{"line":4,"characteristic":"airborne_sound_insulation","as_named":"Airborne sound insulation - R","specification":null,"from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":5,"characteristic":"acoustic_absorption","as_named":"Acoustic absorption - α","specification":null,"from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"see literature","kind":"see_literature"}]},{"line":6,"characteristic":"water_vapour_resistance_factor","as_named":"Water vapour permeability - µ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"10","kind":"number","bound":"=","value":10,"unit":null}]},{"line":7,"characteristic":"thermal_conductivity","as_named":"Thermal conductivity - λ","specification":"EN 12524:2000","from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"0.25 W/m.K","kind":"number","bound":"=","value":0.25,"unit":"W/m.K"}]},{"line":8,"characteristic":"impact_resistance","as_named":"Impact Resistance- →I","specification":null,"from":"declaration","document":"UKSI-00520-013-22","applies":"CE","values":[{"as_printed":"see literature","kind":"see_literature"}]}],"variants":[],"listed_by":[],"note":"Declared by the maker, not tested by Matspec. A value is what the document named beside it stated on the day it was read.","source":"https://media.siniat.co.uk/cert_290614_gb/original/-392906995/dop_uksi-00520-013-22gb_siniat_firemrboard_ukca.pdf?brand=siniat&market=gb","checked":"2026-11-22","page":"https://matspec.io/products/siniat-fire-mr-board","history":{"firstRead":"2026-11-22","lastChanged":"2026-11-22","revisions":2,"changes":"https://matspec.io/api/query"}}