Products · Siniat · Gypsum boards and sheets
Siniat LaDura
Declared by the maker, not tested by Matspec. A value is what the document named beside it stated on the day it was read.
- Maker
- Siniat
- Family
- Gypsum boards and sheets (Pr_25_71_35)
- Type under EN 520:2004+A1:2009
- D, F, H1, I, R
- Declared as
- Siniat LaDura (Gypsum plasterboard type D, F, H1, I, R)
- Intended use, as declared
- General building construction
- Status
- current
- Last checked
- 2026-11-23
What its maker declares
UKCA declaration UKSI-00520-011-24GB, dated 2024-10-29
| Characteristic, as named | For | Declared | Specification cited |
|---|---|---|---|
| Shear strength-shear strength | NPDno performance determined: the maker declares none | ||
| Reaction to fire - R2Freaction to fire | A2-s1,d0 | EN520:2004+A1:2009 | |
| Water vapour permeability - µwater vapour resistance factor | 10 | EN 12524:2000 | |
| Flexural strength - Fflexural strength | 12.5 mm, transverse | 300 N | EN 520:200 4+A1:2009 |
| 12.5 mm, longitudinal | 725 N | ||
| 15 mm, transverse | 360 N | ||
| 15 mm, longitudinal | 870 N | ||
| Thermal resistance - λ | 0.25 W/m.K | EN 12524:2000 | |
| Impact Resistance- →Iimpact resistance | see literaturenot on this document: the maker points to its own literature | ||
| Airborne sound insulation - Rairborne sound insulation | see literaturenot on this document: the maker points to its own literature | ||
| Acoustic absorption - αacoustic absorption | see literaturenot on this document: the maker points to its own literature |
CE declaration UKSI-00520-011-24, dated 2024-10-29
| Characteristic, as named | For | Declared | Specification cited |
|---|---|---|---|
| Shear strength-shear strength | NPDno performance determined: the maker declares none | ||
| Reaction to fire - R2Freaction to fire | A2-s1,d0 | EN520:2004+A1:2009 | |
| Water vapour permeability - µwater vapour resistance factor | 10 | EN 12524:2000 | |
| Flexural strength - Fflexural strength | 12.5 mm, transverse | 300 N | EN 520:200 4+A1:2009 |
| 12.5 mm, longitudinal | 725 N | ||
| 15 mm, transverse | 360 N | ||
| 15 mm, longitudinal | 870 N | ||
| Thermal resistance - λ | 0.25 W/m.K | EN 12524:2000 | |
| Impact Resistance- →Iimpact resistance | see literaturenot on this document: the maker points to its own literature | ||
| Airborne sound insulation - Rairborne sound insulation | see literaturenot on this document: the maker points to its own literature | ||
| Acoustic absorption - αacoustic absorption | see literaturenot on this document: the maker points to its own literature |
The documents these come from
| Document | Number | Dated | Applies | Standard | Assessment | First read | Last checked |
|---|---|---|---|---|---|---|---|
| declaration, at the maker | UKSI-00520-011-24GB | 2024-10-29 | UKCA | EN 520:2004+A1:2009 | System 4 | 2026-11-23 | 2026-11-23 |
| declaration, at the maker | UKSI-00520-011-24 | 2024-10-29 | CE | EN 520:2004+A1:2009 | System 4 | 2026-11-23 | 2026-11-23 |
Names and codes
- UKSI-00520-011-24declaration number
- UKSI-00520-011-24GBdeclaration number
- Siniat LaDuraname
Sizes
No size read yet: sizes are on the maker's data sheet, not its declaration.
Listed by
No seller's listing read yet.
As data
/products/siniat-ladura.json: this page as data, every row, as it stands today. The dated history of changes is in the query layer.
History
| Date | What |
|---|---|
| 2026-11-23 | First read: declaration UKSI-00520-011-24, dated 2024-10-29, 11 declared values on 8 lines. |
| 2026-11-23 | First read: declaration UKSI-00520-011-24GB, dated 2024-10-29, 11 declared values on 8 lines. |