Matspec

Products · Siniat · Gypsum boards and sheets

Siniat Universal MR Board

Declared by the maker, not tested by Matspec. A value is what the document named beside it stated on the day it was read.

Maker
Siniat
Family
Gypsum boards and sheets (Pr_25_71_35)
Type under EN 520:2004+A1:2009
D, F, I, R, H2
Declared as
Siniat Universal MR Board (Gypsum Plasterboard Type D,F,I,R,H2)
Intended use, as declared
General building construction
Status
current
Last checked
2026-11-22

What its maker declares

UKCA declaration UKSI-00520-018-25GB, dated 2025-01-30

Characteristic, as namedForDeclaredSpecification cited
Flexural strength - Fflexural strength12.5 mm, transverse≥300NEN 520:2004+A1:2009
12.5 mm, longitudinal≥725N
15 mm, transverse≥360N
15 mm, longitudinal≥870N
Shear strength-shear strengthNPDno performance determined: the maker declares none
Reaction to fire - R2Freaction to fireA2,-s1,d0 (class A2-s1,d0)EN 520:2004+A1:2009
Airborne sound insulation - Rairborne sound insulationsee literaturenot on this document: the maker points to its own literature
Acoustic absorption - αacoustic absorptionsee literaturenot on this document: the maker points to its own literature
Water vapour permeability - µwater vapour resistance factor10EN 12524:2000
Thermal conductivity - λthermal conductivity0.25 W/m.KEN 12524:2000
Impact Resistance- →Iimpact resistancesee literaturenot on this document: the maker points to its own literature

CE declaration UKSI-00520-018-25, dated 2025-01-30

Characteristic, as namedForDeclaredSpecification cited
Flexural strength - Fflexural strength12.5 mm, transverse≥300NEN 520:2004+A1:2009
12.5 mm, longitudinal≥725N
15 mm, transverse≥360N
15 mm, longitudinal≥870N
Shear strength-shear strengthNPDno performance determined: the maker declares none
Reaction to fire - R2Freaction to fireA2,-s1,d0 (class A2-s1,d0)EN 520:2004+A1:2009
Airborne sound insulation - Rairborne sound insulationsee literaturenot on this document: the maker points to its own literature
Acoustic absorption - αacoustic absorptionsee literaturenot on this document: the maker points to its own literature
Water vapour permeability - µwater vapour resistance factor10EN 12524:2000
Thermal conductivity - λthermal conductivity0.25 W/m.KEN 12524:2000
Impact Resistance- →Iimpact resistancesee literaturenot on this document: the maker points to its own literature

The documents these come from

DocumentNumberDatedAppliesStandardAssessmentFirst readLast checked
declaration, at the makerUKSI-00520-018-25GB2025-01-30UKCAEN 520:2004+A1:2009System 42026-11-222026-11-22
declaration, at the makerUKSI-00520-018-252025-01-30CEEN 520:2004+A1:2009System 42026-11-222026-11-22

Names and codes

Sizes

No size read yet: sizes are on the maker's data sheet, not its declaration.

Listed by

No seller's listing read yet.

As data

/products/siniat-universal-mr-board.json: this page as data, every row, as it stands today. The dated history of changes is in the query layer.

History

DateWhat
2026-11-22First read: declaration UKSI-00520-018-25, dated 2025-01-30, 11 declared values on 8 lines.
2026-11-22First read: declaration UKSI-00520-018-25GB, dated 2025-01-30, 11 declared values on 8 lines.